Int 21 Fn E3 - Novell Netware - Bindery Services - Scan Bindery Object [N]
AH = E3h subfn 37h
DS:SI -> request buffer (see below)
ES:DI -> reply buffer (see below)
Return: AL = status (see AH=E3h/SF=36h)
Notes: this function is supported by Advanced NetWare 1.0+ and Alloy NTNX
the requesting workstation must be logged into the file server with
read access to the bindery object
See Also: AH=E3h/SF=32h,AH=E3h/SF=33h,AH=E3h/SF=38h,AH=E3h/SF=3Ch
Format of request buffer:
Offset Size Description
00h WORD length of following data (max 37h)
02h BYTE 37h (subfunction "Scan Bindery Object")
03h DWORD (big-endian) last object ID
07h WORD (big-endian) type of object
09h BYTE length of object's name
0Ah N BYTEs object's name
Format of reply buffer:
Offset Size Description
00h WORD (call) 0039h (length of following buffer space)
02h DWORD (big-endian) object ID
FFFFFFFFh for first call
06h WORD (big-endian) type of object
08h 48 BYTEs object name (counted string)
38h BYTE object flag (00h static, 01h dynamic)
39h BYTE object's security levels
3Ah BYTE object properties flag (00h no, FFh yes)